University of Sussex
Browse
Chow_2007_BMCNuclearMedicine.pdf (371.81 kB)

Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis

Download (371.81 kB)
journal contribution
posted on 2023-06-08, 19:42 authored by Tiffany W Chow, Shinichiro Takeshita, Kie Honjo, Christina E Pataky, Peggy L St Jacques, Maggie L Kusano, Curtis B Caldwell, Joel Ramirez, Sandra Black, Nicolaas P L G Verhoeff
BACKGROUND As imaging centers produce higher resolution research scans, the number of man-hours required to process regional data has become a major concern. Comparison of automated vs. manual methodology has not been reported for functional imaging. We explored validation of using automation to delineate regions of interest on positron emission tomography (PET) scans. The purpose of this study was to ascertain improvements in image processing time and reproducibility of a semi-automated brain region extraction (SABRE) method over manual delineation of regions of interest (ROIs). METHODS We compared 2 sets of partial volume corrected serotonin 1a receptor binding potentials (BPs) resulting from manual vs. semi-automated methods. BPs were obtained from subjects meeting consensus criteria for frontotemporal degeneration and from age- and gender-matched healthy controls. Two trained raters provided each set of data to conduct comparisons of inter-rater mean image processing time, rank order of BPs for 9 PET scans, intra- and inter-rater intraclass correlation coefficients (ICC), repeatability coefficients (RC), percentages of the average parameter value (RM%), and effect sizes of either method. RESULTS SABRE saved approximately 3 hours of processing time per PET subject over manual delineation (p < .001). Quality of the SABRE BP results was preserved relative to the rank order of subjects by manual methods. Intra- and inter-rater ICC were high (>0.8) for both methods. RC and RM% were lower for the manual method across all ROIs, indicating less intra-rater variance across PET subjects' BPs. CONCLUSION SABRE demonstrated significant time savings and no significant difference in reproducibility over manual methods, justifying the use of SABRE in serotonin 1a receptor radioligand PET imaging analysis. This implies that semi-automated ROI delineation is a valid methodology for future PET imaging analysis.

History

Publication status

  • Published

File Version

  • Published version

Journal

BMC Nuclear Medicine

ISSN

1471-2385

Publisher

BioMed Central

Issue

2

Volume

7

Department affiliated with

  • Psychology Publications

Full text available

  • Yes

Peer reviewed?

  • Yes

Legacy Posted Date

2015-01-22

First Open Access (FOA) Date

2015-01-22

First Compliant Deposit (FCD) Date

2015-01-22

Usage metrics

    University of Sussex (Publications)

    Categories

    No categories selected

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC