Prance, R J, Debray, A, Clark, T D, Prance, H, Nock, M, Harland, C J and Clippingdale, A J (2000) An Ultra Low Noise Electric Potential Probe for Human Body Scanning. Measurement Science and Technology, 11 (3). pp. 291-297. ISSN 09570233
Full text not available from this repository.
Official URL: http://dx.doi.org/10.1088/0957-0233/11/3/318
Abstract
In this paper we describe a new very-low-noise, high-input-impedance probe developed to make non-contact measurements of electrical potentials generated by currents flowing in the human body. With a noise level of 2 µV Hz-1/2 at 1 Hz, down to 0.1 µV Hz-1/2 at 1 kHz, and an operational bandwidth from 0.01 Hz to 100 KHz, this probe would seem well suited to the detection of a wide range of electrical activity in the body.
Item Type: | Article |
---|---|
Schools and Departments: | School of Engineering and Informatics > Engineering and Design |
Depositing User: | Robert Prance |
Date Deposited: | 06 Feb 2012 19:51 |
Last Modified: | 24 Jun 2015 12:22 |