Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values

Tofts, Paul S, Cutajar, Marica, Mendichovszky, Iosif A, Peters, A Michael and Gordon, Isky (2012) Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values. European Radiology, 22 (6). pp. 1320-1330. ISSN 1432-1084

Full text not available from this repository.

Abstract

OBJECTIVE

To model the uptake phase of T(1)-weighted DCE-MRI data in normal kidneys and to demonstrate that the fitted physiological parameters correlate with published normal values.

METHODS

The model incorporates delay and broadening of the arterial vascular peak as it appears in the capillary bed, two distinct compartments for renal intravascular and extravascular Gd tracer, and uses a small-vessel haematocrit value of 24%. Four physiological parameters can be estimated: regional filtration K ( trans ) (ml min(-1) [ml tissue](-1)), perfusion F (ml min(-1) [100 ml tissue](-1)), blood volume v ( b ) (%) and mean residence time MRT (s). From these are found the filtration fraction (FF; %) and total GFR (ml min(-1)). Fifteen healthy volunteers were imaged twice using oblique coronal slices every 2.5 s to determine the reproducibility.

RESULTS

Using parenchymal ROIs, group mean values for renal biomarkers all agreed with published values: K ( trans ): 0.25; F: 219; v ( b ): 34; MRT: 5.5; FF: 15; GFR: 115. Nominally cortical ROIs consistently underestimated total filtration (by ~50%). Reproducibility was 7-18%. Sensitivity analysis showed that these fitted parameters are most vulnerable to errors in the fixed parameters kidney T(1), flip angle, haematocrit and relaxivity.

CONCLUSIONS

These renal biomarkers can potentially measure renal physiology in diagnosis and treatment.

KEY POINTS

• Dynamic contrast-enhanced magnetic resonance imaging can measure renal function. • Filtration and perfusion values in healthy volunteers agree with published normal values. • Precision measured in healthy volunteers is between 7 and 15%.

Item Type: Article
Schools and Departments: Brighton and Sussex Medical School > Clinical and Experimental Medicine
Subjects: R Medicine > RC Internal medicine > RC0071 Examination. Diagnosis Including radiography
Depositing User: Ellen Thomas
Date Deposited: 02 Nov 2012 16:04
Last Modified: 02 Nov 2012 16:04
URI: http://srodev.sussex.ac.uk/id/eprint/42037
📧 Request an update