Chow, Tiffany W, Takeshita, Shinichiro, Honjo, Kie, Pataky, Christina E, St Jacques, Peggy L, Kusano, Maggie L, Caldwell, Curtis B, Ramirez, Joel, Black, Sandra and Verhoeff, Nicolaas P L G (2007) Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis. BMC Nuclear Medicine, 7 (2). ISSN 1471-2385
This is the latest version of this item.
![]()
|
PDF
- Published Version
Available under License Creative Commons Attribution. Download (380kB) | Preview |
Abstract
BACKGROUND
As imaging centers produce higher resolution research scans, the number of man-hours required to process regional data has become a major concern. Comparison of automated vs. manual methodology has not been reported for functional imaging. We explored validation of using automation to delineate regions of interest on positron emission tomography (PET) scans. The purpose of this study was to ascertain improvements in image processing time and reproducibility of a semi-automated brain region extraction (SABRE) method over manual delineation of regions of interest (ROIs).
METHODS
We compared 2 sets of partial volume corrected serotonin 1a receptor binding potentials (BPs) resulting from manual vs. semi-automated methods. BPs were obtained from subjects meeting consensus criteria for frontotemporal degeneration and from age- and gender-matched healthy controls. Two trained raters provided each set of data to conduct comparisons of inter-rater mean image processing time, rank order of BPs for 9 PET scans, intra- and inter-rater intraclass correlation coefficients (ICC), repeatability coefficients (RC), percentages of the average parameter value (RM%), and effect sizes of either method.
RESULTS
SABRE saved approximately 3 hours of processing time per PET subject over manual delineation (p < .001). Quality of the SABRE BP results was preserved relative to the rank order of subjects by manual methods. Intra- and inter-rater ICC were high (>0.8) for both methods. RC and RM% were lower for the manual method across all ROIs, indicating less intra-rater variance across PET subjects' BPs.
CONCLUSION
SABRE demonstrated significant time savings and no significant difference in reproducibility over manual methods, justifying the use of SABRE in serotonin 1a receptor radioligand PET imaging analysis. This implies that semi-automated ROI delineation is a valid methodology for future PET imaging analysis.
Item Type: | Article |
---|---|
Schools and Departments: | School of Psychology > Psychology |
Subjects: | R Medicine > RC Internal medicine > RC0321 Neurosciences. Biological psychiatry. Neuropsychiatry |
Depositing User: | Peggy St Jacques |
Date Deposited: | 22 Jan 2015 08:43 |
Last Modified: | 15 Mar 2017 04:17 |
URI: | http://srodev.sussex.ac.uk/id/eprint/52339 |
Available Versions of this Item
-
Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis. (deposited 21 Jan 2015 10:46)
- Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis. (deposited 22 Jan 2015 08:43) [Currently Displayed]
View download statistics for this item
📧 Request an update